Flashing is what stands between the junction of your roof and a wall and the inside of your home. When that junction is not properly sealed, water works its way behind the roofing material, into the wall cavity, and eventually into the building. Two of the most commonly used flashing types at roof-to-wall junctions are apron flashing and step flashing, and while they serve a similar purpose, they are designed for different situations.
Understanding the difference between the two, where each one is used, and how they work together helps you understand your own roof and gives you the right language to have a clear conversation with your roofer when issues arise.
What Is Apron Flashing and Where Is It Used?
Apron flashing, also called base flashing, is a single continuous piece of metal that runs horizontally across the bottom of a vertical surface where it meets the roof slope. It is bent into an L-shape: one face sits against the vertical surface, and the other lies flat on the roof, directing water away from the wall junction and onto the roof surface below.
You will find apron flashing at:
- The base of a chimney, where the front face of the chimney meets the upslope side of the roof
- The base of a dormer wall where it meets the roof slope
- The base of any wall or structure that sits at a right angle to the direction of the roof slope
- Any low horizontal junction where a continuous seal is needed across the full width of the structure
Apron flashing handles water that runs straight down the face of the vertical structure. On a chimney, the front face (the upslope side) uses apron flashing because water runs directly down that face and needs to be directed clearly onto the roof below. It is a simple, effective solution for a straightforward junction.
What Is Step Flashing and Where Is It Used?
Step flashing is used where a roof slope runs alongside a vertical wall, typically along the side of a dormer, a second-storey wall, or any vertical wall that runs parallel to the direction of water flow on the roof. Unlike apron flashing, which is a single continuous piece, step flashing consists of individual pieces installed in overlapping steps, one at each course of the roofing material.
Each step flashing piece is an L-shaped section of metal. The vertical leg is tucked behind or against the wall cladding, and the horizontal leg sits underneath the next sheet or course of roofing material above. This creates a stepped waterproof barrier that integrates with the roof rather than relying solely on sealant.
You will find step flashing at:
- The sides of a chimney, where the sloping roof surface meets the two side faces of the chimney
- Along the sidewalls of dormers
- Where a lean-to or skillion roof meets the wall of the main building
- Any junction where the slope of the roof runs alongside a vertical wall for an extended length
What Is the Key Difference Between Apron and Step Flashing?
The core difference is this: apron flashing handles a horizontal junction at the base of a wall, while step flashing handles the sloping junction alongside a wall. Water flows differently at each of these junctions, so the flashing solution is different.
Apron flashing works as a single continuous barrier because water at the base of a wall arrives from above (down the face of the wall) and needs to be redirected horizontally onto the roof below. A continuous piece handles this well.
Step flashing works in pieces because water at the side of a wall arrives from the roof surface itself, travelling down the slope. Individual stepped pieces integrate with each course of the roof and shed water outward at every step, preventing it from finding its way behind the junction.
Are Apron and Step Flashing Used Together?
Yes, on chimneys and dormers, both types are typically used at the same structure because there are different junctions on all four sides. For a chimney:
- The upslope face uses apron flashing to handle water running down the chimney face and to direct it around the sides
- The two side faces use step flashing to handle water travelling down the roof slope
- The downslope face typically uses a saddle flashing or cricket to divert water around the back of the chimney
All of these flashings work together as a system. If any one of them fails, water can find a path into the roof structure. A correctly waterproofed chimney on a metal roof in Queensland needs all of these components installed correctly and maintained over time.
We discuss chimney flashing in more depth on our metal roof repairs page.
What Material Is Used for Apron and Step Flashing in Queensland?
In Queensland, both apron and step flashing are most commonly fabricated from Zincalume or Colorbond steel. These materials:
- Are compatible with Colorbond and Zincalume roofing sheets, avoiding galvanic corrosion
- Are resistant to the UV exposure and temperature extremes typical of Queensland conditions
- Can be formed on site or prefabricated to match the specific geometry of the junction
- Are available in matching colours when Colorbond is used, creating a consistent visual finish
Lead is sometimes used for step flashing around chimneys in heritage applications due to its pliability around masonry, but it is less common in new residential work.
How Do You Know If Apron or Step Flashing Has Failed?
The most common signs that wall-junction flashing has failed include:
- Water stains on the ceiling or interior walls near a chimney, dormer, or wall junction
- Visible rust, holes, or lifted edges on the flashing when inspected from the roof
- Cracked or missing sealant at the top edge of the flashing where it meets the wall surface
- Damp or musty smell in rooms adjacent to a chimney or internal wall
Because step flashing consists of multiple individual pieces, one failed section can allow significant water entry while the rest of the system remains intact. A professional inspection identifies exactly which pieces have failed and whether targeted repair or full replacement is the right approach.
Thinking about a complete roof overhaul? See our roof replacement Brisbane page for what is covered in a full project.
Should Flashing Be Replaced During a Roof Replacement?
Yes, always. When we carry out a full roof replacement at Fortified, all flashings are replaced as part of the job. Old flashings are not retained under new roofing because they represent the single most common source of early failure after a re-roofing project. New flashings are correctly profiled to match the new roofing sheets and properly sealed and integrated at every junction.
For full details, visit our metal roof replacement Brisbane page.
We also offer Colorbond roofing Brisbane installations with matching colour-coordinated flashings on every project.
Works Cited
Queensland Building and Construction Commission (QBCC). “Flashing and Weatherproofing Requirements.” QBCC, www.qbcc.qld.gov.au.
Standards Australia. “AS 1562.1: Design and Installation of Sheet Roof and Wall Cladding.” Standards Australia, www.standards.org.au.
Australian Building Codes Board (ABCB). “National Construction Code Volume Two.” ABCB, www.abcb.gov.au.