Of all the flashing challenges on a residential roof, the chimney is the most complex. A chimney is a large vertical structure that penetrates the roof at an angle to the slope, creates multiple junction types on four separate faces, and is typically made from masonry that expands and contracts at a different rate to the surrounding metal roof. Getting chimney flashing right requires several different flashing types working together as a system.
A chimney that is incorrectly or inadequately flashed is one of the most common sources of persistent roof leaks on older Australian homes. This guide explains how each component of a properly flashed chimney works, and what goes wrong when any part of the system fails.
Why Is Chimney Flashing Particularly Challenging?
Several factors make chimneys one of the hardest waterproofing challenges on any roof:
- Four separate faces, each with a different relationship to the roof slope, require different flashing solutions
- Masonry and steel expand and contract at different rates, which over time breaks any seal that relies solely on adhesion
- The position of the chimney on the roof slope determines how much water is directed toward the back of the chimney, which can be a significant volume during heavy Queensland rain
- Mortar joints in the chimney can deteriorate, allowing water to enter through the chimney itself rather than around its base
A chimney that has not been repointed or had its flashing replaced for 20 or more years is a common source of water ingress in older Queensland homes.
What Flashing Components Does a Properly Flashed Chimney Need?
What Does Apron Flashing Do on a Chimney?
Apron flashing, also called base flashing, is installed across the upslope face of the chimney, where water running down the chimney face meets the roof surface. It is a continuous L-shaped piece of metal with one leg against the chimney face and the other lying flat on the roof, directing water away from the chimney junction and onto the roof surface below.
The apron is the first line of defence on the upslope side. Water running down the front of the chimney is caught and directed around the sides. Without a correctly installed apron, this water would run directly into the gap between the chimney and the roofing sheets below.
What Does Step Flashing Do on the Sides of a Chimney?
The two side faces of the chimney run parallel to the roof slope. At these junctions, step flashing is used: individual L-shaped pieces installed in overlapping steps, one at each course of the roofing material. Each step piece has a vertical leg that sits against the chimney face and a horizontal leg that slides under the next course of roofing sheet above.
Step flashing works with the natural water flow on the roof: water travelling down the slope hits each step piece and is directed outward, onto the roof surface, rather than being allowed to work its way behind the junction. The stepped sequence means there is no single point of failure; water would have to work its way back up the steps against gravity to enter behind the system.
What Is Counter Flashing and Why Is It Needed?
Counter flashing, also called cap flashing, is installed over the top of the apron and step flashing and is embedded into the mortar joints of the chimney masonry. It overlaps the base flashing below, preventing water from working its way behind the vertical leg of the base flashing.
Without counter flashing, water running down the face of the chimney can travel behind the base flashing through the gap at the top. Counter flashing eliminates this path. It is embedded into a raked mortar joint and sealed, creating a durable connection between the chimney masonry and the flashing system.
Counter flashing is one of the most commonly missing or incorrectly installed components on older chimney flashing systems. It is also one of the first things to fail when mortar deteriorates, because the mortar joint that secures it can crack and allow the flashing to pull away from the chimney face.
What Is a Chimney Saddle or Cricket?
A saddle, also called a cricket or back gutter, is a small secondary roof structure installed behind the chimney on the downslope side. Its purpose is to divert water around the sides of the chimney rather than allowing it to accumulate against the back of the chimney during heavy rain.
On a wide chimney, a significant volume of water can build up behind the structure during a Queensland storm. Without a saddle, this water has nowhere to go except to find a path through the junction between the chimney and the roof. The saddle creates two mini roof slopes that direct water to either side of the chimney, where it runs onto the main roof surface.
Saddle flashings are required by Australian Standards on chimneys above a certain width. On older homes, the saddle is one of the most commonly absent or failed components of the chimney waterproofing system.
What Causes Chimney Flashing to Fail?
Chimney flashing failure in Queensland homes is usually attributable to one or more of the following:
- Deteriorated mortar joints where counter flashing is embedded, allowing the flashing to pull away from the chimney face
- Failed or missing sealant at the top edge of the base flashing where it meets the masonry
- Corrosion of older galvanised flashings that have reached the end of their service life
- Thermal movement over many years causing flashings to crack or lift at lap joints
- A missing or failed saddle behind the chimney allowing water to pool against the downslope face
- Step flashing that was not correctly embedded behind the cladding or roofing sheets on the side faces
How Do You Know If Your Chimney Flashing Has Failed?
Signs of chimney flashing failure include:
- Water stains on the ceiling of the room directly below or adjacent to the chimney, particularly appearing after rain
- Damp or musty smell in the ceiling space near the chimney
- Visible rust streaks on the roof surface running down from the chimney junction
- Visible gaps, lifted edges, or cracked sealant on the flashing itself when inspected from the roof
- Deteriorated mortar on the chimney face where counter flashing is embedded
If you suspect your chimney flashing has failed, our metal roof repairs team in Brisbane can carry out a thorough inspection and advise the best course of action.
Should Chimney Flashing Be Replaced During a Roof Replacement?
Yes, without exception. When we carry out a full roof replacement at Fortified, all chimney flashings are replaced as part of the project. Retaining old chimney flashings under new roofing sheets is one of the most common causes of early leaks after a re-roofing job, because the old flashings are already at or near the end of their service life and the new roof is expected to last 30 to 50 years.
New chimney flashings are correctly profiled and installed to current standards, with new counter flashing embedded in fresh mortar joints, correctly overlapping base and step flashings, and a saddle installed where required by the chimney dimensions.
For a full overview of what our roof replacements include, see the roof replacement Brisbane page.
We also carry out Colorbond roofing Brisbane installations with fully colour-matched chimney flashings.
How Long Does Properly Installed Chimney Flashing Last?
Quality Zincalume or Colorbond chimney flashing installed to current Australian standards can last the life of the roof, typically 30 to 50 years for modern steel products. However, the sealant at the top edge of the flashing and the mortar joint securing the counter flashing will require inspection and maintenance within that period. Regular inspections, particularly after severe storms, help identify and address these maintenance items before they result in water damage.
See our guide on how long a metal roof lasts in Queensland for context on the full expected service life of your roofing system.
Works Cited
Queensland Building and Construction Commission (QBCC). “Roof Flashing and Waterproofing Standards.” QBCC, www.qbcc.qld.gov.au.
Standards Australia. “AS 1562.1: Design and Installation of Sheet Roof and Wall Cladding.” Standards Australia, www.standards.org.au.
Australian Building Codes Board (ABCB). “National Construction Code.” ABCB, www.abcb.gov.au.